SynapSense® Power Suite 
Overview

Growing IT loads are outstripping the power and cooling capacity in today’s data centers and have become expensive bottlenecks to increasing much needed IT expansion. These issues are compounded by the lack of coordination between the IT and Facilities groups to collectively manage the IT equipment and cooling capacity required to support efficient data center operations. To solve these complex problems, SynapSense has added P3 SmartPlug™ and SmartLink™ to our Power Suite products to capture cabinet and outlet level power metering.
The new Power Suite products enable customers to optimize loads, reduce stranded power and identify available and used capacity in real-time. P3 SmartPlug™ and SmartLink™ are unique capacity management tools that identify available power and leverage SynapSense granular environmental sensing to simultaneously locate cooling capacity. These new additions to the SynapSense Power Suite of products increase resiliency and reduce the risk of overloading by providing immediate alarms for phase or load balancing violations.
The Convergence of Available Power and Cooling for Optimal Server Placement

P3 SmartPlug™ and SmartLink™ Features and Benefits
Locate Server Capacity While Tracking Cooling Trends

- Wirelessly transmits current (average and peak), demand power (kW), apparent power (kVa), utility phase and U-space every 15 minutes
- Vendor agnostic: wirelessly gathers data from a variety of RPDU or strip vendors
- Intuitive visualization overlays power and thermal views to support capacity planning for both power and cooling simultaneously
- Identify and locate specific amount of capacity
- Cost effectively retrofit basic strips with pay-as-needed power monitoring
- Identify and reduce stranded power by understanding actual server and cabinet level power usage
- Accurately plan for IT load changes with real-time capacity information
- Common software interface provides robust visualization and trending of cabinet and server PDU strip power data
- Prevents phase overload with immediate alert notification
SynapSense® Power Metering and Branch Circuit Monitoring
SynapSense® Power Metering and Branch Circuit Monitoring (BCM) are providing data center operators robust tools to further improve their data center energy efficiency. Power metering is utilized to measure the data center cooling infrastructure and overall IT load. Branch Circuit Monitoring enables circuit-level monitoring to capture power by rack or cabinet. It supports IT load balancing and capacity management.
Branch Circuit Monitoring
The BCM solution interfaces via split-core CTs with PDU circuit panels or RPPs and supports up to two 42-circuit panels. BCM is used to monitor individual circuits to prevent overloading and costly downtime. The solution monitors amps, voltage, power factor, and energy. Combined with the SynapSense Power Suite console, BCM will help data center managers track and manage the power usage through all power distribution equipment with rack-level visibility. Our Power Suite products allows for monitoring of circuit and rack-level power, leading to phase balancing and optimization of loading across PDU’s.
PowerLogic Power Metering
The PowerLogic ION 6200 power meter is a high-quality, low-cost solution for metering and monitoring energy usage. The metered data is integrated in the Power Suite console. Understand your facility’s electrical usage patterns, total energy consumption and power demand in order to establish a baseline for implementing energy savings initiatives and validating results.